PROJECTS
Ammonia Horizontal Liquid Receiver 1676ID x 6000 Shell to AS1210 Class 2B, May 2017. Britannia Jahco mechanical design and fabricate 1 off Ammonia Horizontal Liquid Receiver 1676ID x 6000 Shell to AS1210 Class 2B, Design Pressure 1500 kpag. The liquid receiver were hydrostatically tested, fully drained, clean internally and using hot air to dry…
Read More965Dia Gas Filter Housing for Gas Liquid Processing, AS1210-Class 2A, May 2017. Design, Third Party Party Review, Design Register with Statutory Authority, Fabricate, NDE to Class 2A and Client Specification, Hydrostatic Test and Blast & paint to Specification. The vessel is a 965Dia x 4150 shell length Gas Filter Housings for Gas Liquid Processing…
Read More2032Dia Vertical Vessel for flare column welded to ASME IX for Aereon/Jordan Flare technology. August 2016. We were contracted to supply material and qualified personnel to fabricate 1 off 2032Dia Vertical Vessel for flare column welded to ASME IX from Aereon/Jordan Flare technology design. Main Shell, End and Cone ASTM A516 70 and Flanges…
Read MoreCarbon Dioxide Liquid Receiver 914ID x 3600 Shell to AS1210 Class 2B, December 2015. Britannia Jahco mechanical design and fabricate 1 off Carbon Dioxide Liquid Receiver 914ID x 3600 Shell to AS1210 Class 2B Design pressure 4000kpag. The vessel were hydrostatically tested, fully drained, clean internally and using hot air to dry internal before…
Read More1118 Dia Gas Coalescer Housing, 10200 kpag to AS1210 Class 1 for Pall Australia. September 2015 Britannia Jahco design and supply 1 off 1118 Dia Gas Coalescer Housing, 10200 kpag to AS1210 Class 1 for Pall Australia. The Vessel comes with GD Bandlock Quick Opening Closure rated 900lbs. The vessel completed successfully and installed…
Read More711Dia KMR Project for Exxon Crude De-etahnizer Heater AES type Shell and Tube Heat Exchanger Sour service, AS1210-Class 1 & TEMA R, FEB 2015. We tender for the De-Ethaniser Heat Exchanger for the Exxon Kipper Mercury Removal project in early 2014 and received the contract in July 2014. We design, Fabricate, test, paint, and…
Read MoreAPLNG Compressor Station 30KL Air Receiver, April 2014. Britannia Jahco Design, Design Review, Fabricate, test and paint 2 off 30KL Air Receivers for Gardner Denver / APLNG Compressor Station. Vessels were 2134ID x 7600mm Shell length, design to AS1210-Class 2B 1035kpag/FV including nozzle loadings and coating internal & external. Factory Tested and Despatch in…
Read More990ID Cyclone Scrubber Vessel AS1210-Class 2A for Newcrest mine – January 2013. Britannia Jahco was contracted to redesigned and supply 1 off 990ID Cyclone Scrubber Vessel to AS1210-Class 2A for Newcrest mine in WA. Design/Design Registration suitable for use in WA DOIR, completed and delivered to site in January 2013.